VM600 IOC16T 200-565-000-013 200-565-101-013 Input / Output Card Type IOC 16T

] 16 channel interface card for use with the VM600 Series CMC 16 (Condition Monitoring Card)
] Screw terminal strip connectors (48 terminals)
] Ensures EMI protection for all inputs
] Provides signal conditioning for all inputs
] Channel functions selectable via DIL switches
] First 4 channels can be selected as tacho or dynamic inputs (i.e. vibration)
] Last 12 channels can be selected as dynamic or process inputs
] Inputs can be routed via VM600 Raw Bus and Tacho Bus
] On-board isolated serial RS-485 communication option
] Live insertion / removal of cards

Category:

Description

VM600 IOC16T 200-565-000-013 200-565-101-013 Input / Output Card Type IOC 16T

] 16 channel interface card for use with the VM600 Series CMC 16 (Condition Monitoring Card)
] Screw terminal strip connectors (48 terminals)
] Ensures EMI protection for all inputs
] Provides signal conditioning for all inputs
] Channel functions selectable via DIL switches
] First 4 channels can be selected as tacho or dynamic inputs (i.e. vibration)
] Last 12 channels can be selected as dynamic or process inputs
] Inputs can be routed via VM600 Raw Bus and Tacho Bus
] On-board isolated serial RS-485 communication option
] Live insertion / removal of cards

The IOC 16T Input / Output Card acts as a signal interface for the VM600 series CMC 16 (Condition
Monitoring Card). It is installed in the rear of an ABE 04X or ABE 055 (Portable CMS) rack, and
connects directly to the rack backplane via two connectors.

VM600-IOC4T

Each IOC 16T is associated with a specific CMC 16 and is mounted directly behind it in the rack. The
IOC 16T contains a terminal strip to connect the transmission cables coming from transducers and
conditioners. However, if these signals are already available via the VM600 backplane ‘Raw Bus’ and
‘Tacho Bus’ lines, then these can be selected directly without any need for additional wiring.
The card protects all inputs against electromagnetic interference (EMI) and signal surges and also meets
EMC (electromagnetic compatibility) standards.
Tacho inputs, signals from accelerometers, velocimeters and proximity probes, or any dynamic or
quasi-static signals are conditioned by dedicated circuitry which performs tasks such as pulse shaping,
level adjustment and AC/DC selection. Micro-switches (DILs) are provided to facilitate
selection of conditioner and access method (i.e. screw terminals or backplane). The IOC 16T also
provides isolation from the plant and ensures feedthrough of inputs to the CMC 16.
Two methods of communication are supported; VMEbus connection to a CPU M module in slot 0 of
the VM600 rack and subsequent Ethernet link, or direct isolated multi-drop RS-485 serial connection1 via RJ connectors provided on the IOC 16T

 