VM-600 IOC4T VM600 IOC4T input/output card
Product description
IOC4T card
The lOC4T input /output card acts as a signalinterface for the VM600 series MPC4 machineryprotection card, from Meggitt’s Vibro-Metereproduct line.lt is installed in the rear ofa yM600rack and connects directly to the rack backplanevia two connectors.
Each lOC4T card is associated with a
coresponding MPC4 card and is mounteddirectly behind it in the wM600 rack (ABE04x orABE056).The lOC4T operates in slave mode andcommunicates with the MPC4, throughconnector P2, using an Industry Pack (lP)interface.
The front panel of the lOC4T (rear of the VM600rack) contains terminal strip connectors for wiringto the transmission cables coming frommeasurement chains (sensors and /or signalconditioners).The screw-terminal connectors arealso used to input all signals from and output allsignals to any external control system.
The lOC4T card protects all inputs and outputsagainst electromagnetic interference (EMl) andsignal surges and also meets electromagneticcompatibility (EMC) standards.
The lOC4T connects the raw dynamic (vibration)and speed signals from the sensors to the MPC4.These signals,once processed, are passed backto the lOC4T and made available on the terminalstrip on its front panel (rear of VM600). For thedynamic signals, four on-board digital-to-analogconverters(DACs) provide calibrated signaloutputs in the range 0 to 10 v.in addition, four on-board voltage-to-curent converters allow thesignals to be provided as current outputs in therange 4 to 20 mA (jumper selectable).
The lOC4T contains four local relays that can beattributed to any specific alamm signals undersoftware control. For example, these may be usedto signal an MPC4 fault or a problem detected bya common alarm (Sensor OK, Alarm and Danger)in a typical application.
In addition, 32 digital signals representing alarmsare passed to the rack backplane and may beused by optional RLCl6 relay cards and / or lRC4intelligent relay cards mounted in the rack(jumper selectable).
Product parameter
• From the Vibro-Meter® product line
• Signal interface card with 4 dynamic signal inputs and 2 tachometer (speed) inputs, for the MPC4 machinery protection card
• Screw-terminal connectors (48 terminals) for all input/output connections
• Contains 4 relays which can be attributed to alarm signals, under software control
• 32 fully-programmable open-collector outputs (jumper selectable) to IRC4 and RLC16 relay cards
• Buffered “raw” sensor signals and analog output signals (voltage or current) for vibration channels
• EMI protection for all inputs and outputs
• Live insertion and removal of cards (hot-swappable)
• Available in “standard” and “separate circuits” versions
Application field
The VM-600 IOC4T is an input/output card primarily used in industrial vibration monitoring and control systems. Its versatility and reliability make it widely used in many fields.
Specifically, the VM-600 IOC4T can be widely used in industrial automation, process control, material testing, machine tool positioning and other fields. In these areas, it can help users achieve efficient equipment monitoring, fault diagnosis and preventive maintenance, thereby improving production efficiency and equipment reliability.
In addition, the VM-600 IOC4T also provides a variety of input and output types, including contact input, analog input, pulse input, relay output and analog output, which makes it suitable for different applications. At the same time, it also has communication interfaces, such as Modbus, Ethernet, etc., which can exchange data and communicate with other devices and control systems.
Overall, the VM-600 IOC4T is a powerful, flexible and reliable input/output card with a wide range of applications in the field of industrial vibration monitoring and control systems.