1420-V1P-ENT power monitoring device

Accuracy: 1.00%
Alarm: Yes
Communication: None (but optional)
Frequency rating: 45-65Hz
Interface: Built-in LCD
Output: 2 pulses
Voltage (via direct connection or VT/PT) : 120/208V LL
Input impedance: 5(6)A, <0.2VA
Current overload: 6 A, continuous at 50/60 Hz
Control Power Supply: Range: 100 to 240V AC (48 to 62Hz)
Voltage overload: 2 x Vnom (Vnom is the rated voltage of the module) for 500 ms
Coupling type: with CT
Temperature drift: ≤ 200 ppm/°C

Category:

Description

1420-V1P-ENT power monitoring device

Product Description

Allen-Bradley® PowerMonitor™ 500 is a power monitoring device manufactured by Rockwell Automation, Inc. Model 1420-V1P-ENT is one of the products in this family. The following are the detailed features and parameters of the product:

Power measurement: Can measure voltage, current, power, energy, demand and power factor.
Communication type: Support Modbus RTU or EtherNet/IP™ communication protocols.
Analog outputs: Optional two analog outputs for variable speed process control.
Digital relay output: Optional two digital relay outputs.
Configure alarms: Four configurable alarms are provided to notify specific conditions.
Display and data communication: allows you to centrally record data and display it locally.
LCD display: Provides instant and accurate sub-metering data to help you understand your energy usage.
Simplified installation: Simple configuration on the device, reducing installation components and space.
Integration with RSEnergyMetrix® software: A complete energy management solution.

1420-V2-ENT

Product parameter

Accuracy: 1.00%
Alarm: Yes
Communication: None (but optional)
Frequency rating: 45-65Hz
Interface: Built-in LCD
Output: 2 pulses
Voltage (via direct connection or VT/PT) : 120/208V LL
Input impedance: 5(6)A, <0.2VA
Current overload: 6 A, continuous at 50/60 Hz
Control Power Supply: Range: 100 to 240V AC (48 to 62Hz)
Voltage overload: 2 x Vnom (Vnom is the rated voltage of the module) for 500 ms
Coupling type: with CT
Temperature drift: ≤ 200 ppm/°C
Current range (via CT) : 5 A nominal (6 A Max)
Rated input: System type: 1, 2, or 3 phases
Current type: Electrical isolation from built-in CT
Methods: Real RMS was used to measure the distorted waveform
Sampling rate: 3840 sAles/s at 60 Hz, 3200 sAles/s at 50 Hz
Energy additional error: according to EN62053-21 ANSI C12.1, impact Class B according to EN50470-3, EN62053-23
Current sensing: Nominal: 5 A
Voltage sensing: Nominal: 120V AC LN, 208V AC LL Range: 40 to 144V AC LN RMS, 70 to 250V AC LL RMS
Pulse (digital) output: Yes
Front dimension: 96 mm
Height: Front dimension: 96 mm
Width: Front dimension: 96 mm
Accuracy: Voltage, nominal: 120V AC LN, 208V AC LL @ 25°C ±5°C, R.H. ≤ 60% @ 48… 62Hz
System and single-phase mean and maximum variables: Yes
Real-time clock function: Yes
Optional pair of digital (relay) outputs: Yes
Run hour counter: 8+2 digits
Energy measurement (import/export) : KWh and kVARh
Front protection class: IP65, NEMA 4X, NEMA 12
Measurement value display: four lines, each line 4 digits
Energy value display: tens digit and positive/negative sign
Universal power supply: 120/240V AC 50/60 Hz or 120/240V DC
Income grade energy measurement: According to ANSI C12.1 Class 1.0, ANSI C12.1
Configurable virtual alarms: up to four

Application field

Installation and wiring:

Provide detailed installation and wiring instructions to ensure equipment is properly installed and complies with all applicable codes, standards and regulations.
A variety of wiring diagrams are available, including connections for three-phase, two-phase and single-phase systems.
Communication:

Supports EtherNet/IP™ and Modbus TCP/IP communication for easy integration with existing energy monitoring systems.
Environmental specifications:

Storage temperature: -30 to +70°C
Operating temperature: -25 to +40°C
EMC Specifications:

Noise suppression CMRR: 100 dB, 48 to 62 Hz
Electrostatic discharge: 15 kV air discharge
Rf suppression: according to CISPR 22
Electromagnetic compatibility: According to EN62052-11
Withstand voltage: 4 kV AC rms for 1 minute
Size and weight:

Module bracket: 96 x 96 x 50 mm (3.78 x 3.78 x 1.97 in.)
Digital and analog output type modules: 89.5 x 63 x 16 mm (3.52 x 2.48 x 0.63 in.)
Serial and Ethernet communication type modules: 89.5 x 63 x 20 mm (3.52 x 2.48 x 0.79 in.)
Weight: Approx. 400 g (0.88 lb) (including packaging)
Settings:

It can be configured using software tools
Configurable alarm
Voltage rotation phase sequence

Other related product recommendations:

MVI56-ADM  Prosoft  Programmable Application Development Module
BMXCPS2010  Schneider  Standard power module
BMXDDO6402K  Schneider  discrete DC output module
BMXDDI3202K  Schneider  discrete input module
PCI-6221  779066-01  Multifunction I/O Device
SHC68-68-EPM  NI  Multifunctional cable
05701-A-0361  Backplane Serial communication controllers and monitors
AI03  ABB   AI module  2-3-4 Wire RTDs
AI02J  ABB   AI module  2-3-4 Wire RTDs
IOC-555-D 17-550555-001  GE  Electronic components
PC834-001-T  PACIFIC SCIENTIFIC Brushless Servo Drive
8440-1666 B  SPM-D11/LSXR features 12/24 VDC power supply
IC670ALG310  GE  voltage-source analog output module
PM866K01 3BSE050198R1  AC800M processor unit
81001-340-71-R  Allen Bradley  Inverter processing module
PXI-8423  NI  PXI-8423/2 RS-485 Interface
AD02  ABB   AI module  2-3-4 Wire RTDs
MVME55006E-0163  MOTOROLA  VMEbus Single-Board Computer
531X301DCCAFG2  GE  DRIVE CONTROL BOARD
A6370D  Emerson  A6370 Overspeed Protection Monitor
1715-TASOB8DE  Allen Bradley  termination assembly
4PP065.0571-X74F  Power Panel PP65
2094-BC02-M02   Kinetix 6000 Integrated Axis Module (IAM)
MVI56E-MCM  ControlLogix series communication module
1769-L32E  CompactLogix Modular controller
DI810  16  Digital Input  module

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com