The 3500/50 can be configured to provide key phase signals to the 3500 frame backplane for use by other monitors, so no more
Install key phase module in frame. The 3500/50 also has a peak-hold feature; It can store how high the machine has been
Rotational speed, high reversal speed, or number of reversals (depending on the channel type selected). These spikes can be reset by the user.
Application shows that
• The Bentley Nevada Tachometer module is not used alone or as a component for speed control or overspeed protection systems.
• The Bentley Nevada tachometer module does not provide protection redundancy and speed response for speed control or overspeed protection systems.
• Analog proportional output is only used for data collection, chart recording or display. In addition, the RPM warning set point is only used for
Purpose of notification.
• Magnetic sensors do not use the reversal option because these sensors do not provide a clear edge for the detection circuit at low speeds,
This will cause
An incorrect reversal indication.
• The zero speed option is not recommended for magnetic sensors because these sensors do not provide clarity to the detection circuit at low speeds
The edge.
Each tachometer module receives one or two eddy current or magnetic sensor signals ranging from +10.0V to
-24.0V, signal beyond this range is restricted in the module. Alarm point setting: One level alarm can be set by tachometer for each measured value
Settings. In addition, the secondary alarm can be set by any two values of the tachometer measurements. All alarm points are configured by software.
Alarm points are adjustable, usually at full scale
The value ranges from 0 to 100%. The alarm delay can be programmed by the software and set as follows: Alarm 1: from 1 to 60 seconds, adjust the interval
The interval is 1 second;
Alarm 2: from 1 to 60 seconds, adjust the interval to 0.1 seconds. The meaning of the LED lights on the front panel is similar to that of the previously mentioned modules.
1. The status leds
2. Buffer sensor output
3. I/O module with internal terminals
4. I/O module with external terminals
I/O module, TMR, with external terminals
6. I/O module with internal safety bars and terminals