GE D20 EME 10BASE-T Substation controller

1, the current between a phase jack alarm light, and alarm sound: this phase current open circuit or load exceeds the actual output range, check the wiring and load and try again. 2, power amplifier power supply or output voltage immediately jump power amplifier, power indicator flashing red light and alarm sound: turn on the
Details
100031593.10 LSU-112DG

DEIF LSU-112DG 100031593.10 distributor

①, current protection: (according to the setting principle of protection, protection range and principle characteristics) A, overcurrent protection - is to avoid the maximum load current that may appear in the protected equipment or line to set. Non-fault current, such as large motor starting current (short time) and traversing short circuit current, to ensure the
Details

ICS TRIPLEX T8800 5600633 Terminal board

(1) Monitor the normal operation of the power system. When the protected power system component fails, the relay protection device of the component should quickly and accurately issue a trip command to the circuit breaker nearest to the faulty component, so that the faulty component can be interrupted from the power system in time, so
Details

ICS TRIPLEX T8850 5600389 Terminal board

The relay protection device should meet the requirements of reliability, selectivity, sensitivity and quickness: the four "sex" is closely related, both contradictory and unified. selectivity -- Indicates that the fault is first removed by the protection of the faulty device or circuit breaker. When the protection of the faulty device or circuit breaker refuses to
Details
0745648E 0745745Q

ABB 0745745Q 0745648E Circuit board, Sensor-CPU

A. Sampling unit -- it will be the physical quantity (parameter) in the operation of the protected power system through electrical isolation and conversion into the signal acceptable by the comparison identification unit in the relay protection device. It is composed of one or several sensors such as current and voltage transformers. B. Comparison identification
Details

369-HI-R-M-0-0-0-E GE Relay protection device

The relay protection is mainly the principle that the electrical volume (current, voltage, power, frequency, etc.) changes when the components in the power system occur short circuit or abnormal condition constitute the relay protection action. There are other physical quantities, such as the increase of a large number of gas and oil flow speed or
Details
CE3008 KJ2005X1-MQ1/12P6381X022

CE3008 Communication module

In comparison, the use of wireless DATA transmission module to establish a dedicated wireless data transmission mode than other ways have the following advantages, the following introduces the use of data-6106 wireless data transmission module to establish a dedicated wireless data transmission mode compared to the advantages of wired communication. Cheap cost Cable communication mode
Details
5SHX2645L0004 3BHB003154R0101

3BHB003154R0101 3BHL000389P0104 IGCT module

Classification of IGCT In terms of internal structure, IGCT can be divided into the following three categories: (1) Asymmetric It is a pure PNPN thyristor structure. The device can withstand high voltage in the forward direction, but it does not have the ability to withstand reverse voltage and cannot flow through reverse current. It is
Details

DEIF SCM-1 Measurement module

The SCM-1 module consists of three boards connected by an eight wired bus on the front side (not the backplane bus). The boards for SCM-1 are named SCM-A, SCM-B and SCM-C and these names can be found on the boards. SCM-A board: Two relay-boards OPR-1 can be mounted. One for output for a mechanical speed
Details