VM600-CSA 204-040-100-211 VM600Mk2/ VM600 ABE040 and ABE042 system racks

The VM600Mk2/VM600 ABE040 and ABE042 system racks are used to house hardware for the
VM600Mk2/VM600 series of machinery protection and/or condition monitoring systems, from
Meggitt’s vibro-meter® product line.
Two types of VM600Mk2/VM600 ABE04x system rack are available: the ABE040 and the ABE042.
These are very similar, differing only in the position of the mounting brackets. Both racks have a
standard height of 6U and provide mounting space (rack slots) for up to 15 single-width
VM600Mk2/VM600 modules (card pairs), or a combination of single-width and multiple-width
modules (cards). These racks are particularly suitable for industrial environments, where
equipment must be permanently installed in 19″ cabinets or panels.

Category:

Description

VM600-CSA 204-040-100-211 VM600Mk2/ VM600 ABE040 and ABE042 system racks

The VM600Mk2/VM600 ABE040 and ABE042 system racks are used to house hardware for the
VM600Mk2/VM600 series of machinery protection and/or condition monitoring systems, from
Meggitt’s vibro-meter® product line.
Two types of VM600Mk2/VM600 ABE04x system rack are available: the ABE040 and the ABE042.
These are very similar, differing only in the position of the mounting brackets. Both racks have a
standard height of 6U and provide mounting space (rack slots) for up to 15 single-width
VM600Mk2/VM600 modules (card pairs), or a combination of single-width and multiple-width
modules (cards). These racks are particularly suitable for industrial environments, where
equipment must be permanently installed in 19″ cabinets or panels.

The different versions of ABE04x system rack enable different mounting options to support
various markets and applications.
The VM600 system rack has an integrated VME backplane which provides the electrical
interconnections between the installed VM600Mk2/VM600 modules (cards): power supply,
signal processing, input /output, relay and CPUx “rack controller”. It also includes a power
supply check relay, available at the rear of the rack, which is used to indicate that the installed
RPS6U rack power supplies are operating normally.
Either one or two RPS6U rack power supplies can be installed in a VM600Mk2/VM600 ABE04x system
rack. A rack with one RPS6U power supply (330 W version) supports the power requirements for a full
rack of modules (cards) in applications with operating temperatures up to 50°C (122°F).

VM600-CSA 204-040-100-211

Alternatively, a rack can have two RPS6U power supplies installed in order to either support rack
power supply redundancy or in order to supply power to the modules (cards) non-redundantly

over a wider range of environmental conditions (see Power supply on page 4).

VM600Mk2/VM600 processing modules (cards) are installed in the front of the rack and the
associated input/output modules (cards) are installed in the rear. The input/output modules
(cards) provide connectors for the connection of sensors/measurement chains and for the sharing
of various signals with external systems such as a DCS or PLC.
In general, VM600Mk2/VM600 ABE04x system racks are configured in the factory before delivery so
they are supplied ready-to-use. Optionally, each module (card) can be reconfigured to meet the
needs of a particular machinery monitoring application using the appropriate software
package from Meggitt vibro-meter®: VM600 MPSx or VibroSight®.
For further information, contact your local Meggitt representative.

 

Please contact Sunny sales@xiongbagk.cn for the best price.