VM600 RPS6U 200-582-600-013 rack power supplies

KEY FEATURES AND BENEFITS
• From the vibro-meter® product line
• Power supply for VM600Mk2/VM600 ABE04x 19″ system racks with a height of 6U
• Input: AC-input and DC-input versions
• Outputs: +5 VDC and ±12 VDC
• Output over-voltage, short-circuit and overload protection
• Status indicators
• High-power, high-performance, highefficiency
• Minimal derating within the operating temperature range

Category:

Description

VM600 RPS6U 200-582-600-013 rack power supplies

KEY FEATURES AND BENEFITS
• From the vibro-meter® product line
• Power supply for VM600Mk2/VM600 ABE04x 19″ system racks with a height of 6U
• Input: AC-input and DC-input versions
• Outputs: +5 VDC and ±12 VDC
• Output over-voltage, short-circuit and overload protection
• Status indicators
• High-power, high-performance, highefficiency
• Minimal derating within the operating temperature range
APPLICATIONS
• VM600Mk2/VM600 machinery protection and/ or condition monitoring systems
• One RPS6U rack power supply powers a full rack of modules (cards)
• Two RPS6U rack power supplies enable rack power supply redundancy

DESCRIPTION
The VM600Mk2/VM600 RPS6U rack power supplies are designed for use in the VM600Mk2/VM600
series of machinery protection systems and condition and performance monitoring systems,
from Meggitt’s vibro-meter® product line. A VM600Mk2/VM600 RPS6U rack power supply is
installed in the front of a VM600Mk2/VM600 ABE04x system rack (19″ system racks with a standard
height of 6U) and connects via two high-current connectors to the VME bus of the rack’s
backplane. The RPS6U power supply provides +5 VDC and ±12 VDC to the rack itself and all
installed modules (cards) in the rack via the rack’s backplane.

Vibro-meter-VM600-RPS6U

Either one or two VM600Mk2/VM600 RPS6U rack power supplies can be installed in a VM600Mk2/ VM600 ABE04x system rack. A rack with one
RPS6U power supply (330 W version) supports the power requirements for a full rack of modules (cards) in applications with operating
temperatures up to 50°C (122°F).
Alternatively, a rack can have two RPS6U power supplies installed in order to either support rack power supply redundancy or in order to supply
power to the modules (cards) non-redundantly over a wider range of environmental conditions.
A VM600Mk2/VM600 ABE04x system rack with two RPS6U power supplies installed can operate redundantly (that is, with rack power supply
redundancy) for a full rack of modules (cards).
This means that if one RPS6U fails, the other will provide 100% of the rack’s power requirement so that the rack will continue to operate, thereby
increasing the availability of the machinery monitoring system.
Note: This is known as a redundant RPS6U rack power supply configuration.
A VM600Mk2/VM600 ABE04x system rack with two RPS6U power supplies installed can also operate non-redundantly (that is, without rack power
supply redundancy). Typically, this is only necessary for a full rack of modules (cards) in applications with operating temperatures above
50°C (122°F), where RPS6U output power derating is required.

 